Partial discharge and dielectric response behaviour of insulation systems for high voltage rotating machines under electrical stress

verfasst von
Mohsen Farahani, H. Borsi, E. Gockenbach, Martin Kaufhold
Abstract

In order to understand how the partial discharge (PD), dissipation factor and dielectric response measurements can reflect the changes in the groundwall insulation of high voltage rotating machines due to electrical stress which lead to insulation degradation, an electrical stress has been applied on insulation system of high voltage rotating machines and the change of PD pattern, dissipation factor as function of the applied test voltage and dielectric response in time and frequency domain were studied. As test object, actual stator bars were used, which are based on the epoxy VPI technology, according to manufacturer's standard.

Organisationseinheit(en)
Fachgebiet Hochspannungstechnik und Asset Management (Schering-Institut)
Externe Organisation(en)
Siemens AG
Typ
Konferenzaufsatz in Fachzeitschrift
Journal
Annual Report - Conference on Electrical Insulation and Dielectric Phenomena, CEIDP
Seiten
271-274
Anzahl der Seiten
4
ISSN
0084-9162
Publikationsdatum
2004
Publikationsstatus
Veröffentlicht
Peer-reviewed
Ja
ASJC Scopus Sachgebiete
Allgemeiner Maschinenbau