Set-Up for Space Charge Measurement with LIPP-Method During Aging of Polymeric Insulating Materials Under High DC Voltage
- verfasst von
- Henry Hirte, Sebastian Braun, Stefan Kornhuber, Peter Werle
- Abstract
This contribution introduces an adapted test set-up, which will be used to develop new methods for the determination of voltage endurance tests of insulating materials subjected to high DC voltages. The set-up combines the voltage endurance test for approximately 80 - 100 kV/mm of five 1 mm thick samples simultaneously and the space charge measurement up to the break down voltage of several polymeric insulating materials by using the LIPP-method. All components are designed to measure the space charges during the aging process until the breakdown of the sample. The set-up is also designed for examination under different temperatures from 20 to 80{circ}mathrm{C} and different contact pressures. The components are described in detail to provide a template for constructing further test set-ups and developing optimization with using the LIPP-method.
- Organisationseinheit(en)
-
Fachgebiet Hochspannungstechnik und Asset Management (Schering-Institut)
- Externe Organisation(en)
-
Hochschule Zittau/Görlitz
- Typ
- Aufsatz in Konferenzband
- Seiten
- 494-497
- Anzahl der Seiten
- 4
- Publikationsdatum
- 2022
- Publikationsstatus
- Veröffentlicht
- Peer-reviewed
- Ja
- ASJC Scopus Sachgebiete
- Elektrotechnik und Elektronik, Polymere und Kunststoffe
- Elektronische Version(en)
-
https://doi.org/10.1109/ICD53806.2022.9863459 (Zugang:
Geschlossen)