Eklund L, Lorin P, Werle P, Köstinger P, Oktem M. Increase Transformer Reliability and Availability. 2007.
Mehr...
Farahani M, Gockenbach E, Borsi H. Dielectric Response Measurement to Evaluate the Moisture Content in Insulating Systems of High Voltage Rotating Machines. 2007.
Mehr...
Farahani M, Borsi H, Gockenbach E. Ermittlung der physikalischen Veränderungen in Epoxidharz-Glimmer-Isolierungen infolge thermischer Überbeanspruchung mit Hilfe von Teilentladungs- und Verlustfaktormessungen. 2007.
Mehr...
Farahani M, Borsi H, Gockenbach E. Partial Discharge Behavior of Insulating Systems for High Voltage Rotating Machines under Electrical Stress. 2007.
Mehr...
Farahani M, Borsi H, Gockenbach E. Study of capacitance and dissipation factor tip-up to evaluate the condition of insulating systems for high voltage rotating machines. Electrical engineering. 2007 Mär;89(4):263-270. doi: 10.1007/s00202-006-0011-9
Mehr...
Fofana I, Borsi H, Gockenbach E, Farzaneh M. Aging of transformer insulating materials under selective conditions. European Transactions on Electrical Power. 2007 Sep;17(5):450-470. doi: 10.1002/etep.134
Mehr...
Gockenbach E, Borsi H. Aktueller Stand der Monitoring- und Diagnoseverfahren für Leistungstransformatoren. Elektrotechnik und Informationstechnik. 2007 Dez;124(12):435-442. doi: 10.1007/s00502-007-0494-8
Mehr...
Gockenbach E, Hauschild W, Schierig S, Muhr M, Lick W, Berlijn SM. Challenges on the measuring and testing techniques for UHV AC and DC equipment. 2007.
Mehr...
Gockenbach E. Description and Interpretation of the New Evaluation Procedure for Impulse Voltages in IEC 60060-1 and 61083-2. 2007.
Mehr...
Gockenbach E, Farahani M. Dielectric Response Measurements as Life Assessment Technique for Insulation Systems. 2007.
Mehr...
Gockenbach E, Farahani M. Partial Discharge Measurement as Diagnostic Tool for Insulation System in High Voltage Rotating Machines. 2007.
Mehr...
Kouzmine O, Werle P, Szczechowski J. Reproducibility of the FRA-Measurements as an Effective Method for Diagnostic of Power Transformers. 2007.
Mehr...
Kouzmine O, Werle P. Studies on Main Influencing Factors and Reproducibility of FRA Measurements. 2007.
Mehr...
Reuter M, Gockenbach E, Borsi H. A Numerical Method for 3D-Description of a Scattered Characteristic Aging Data from Multistress Aged XLPE-Cable Insulation. 2007.
Mehr...
Setayeshmehr A, Eichler C, Akbari A, Borsi H, Gockenbach E. Condition Evaluation of Oil-Pressboard Insulation by Fourier Transform Of Time Domain Dielectric Response. 2007.
Mehr...
Setayeshmehr A, Fofana I, Akbari Azirani A, Borsi H, Gockenbach E. Effect of Temperature on Dielectric Response of Transformer Insulation. 2007.
Mehr...
Setayeshmehr A, Akbari A, Borsi H, Gockenbach E, Fofana I. Winding Diagnostic by On-line Transfer Function Determination via Power Transformer Bushing Tap. 2007.
Mehr...
Szczechowski J, Borsi H, Gockenbach E. Partial Discharge Measurement and Localization on Power Transformers. 2007.
Mehr...
Szczechowski J, Werle P, Steiger M, Kouzmine O, Borsi H, Gockenbach E. Partial Discharge Measurements and Localizations on Power Transformers. 2007.
Mehr...
Szczechowski J, Borsi H, Gockenbach E. Repeatability of FRA Measurements and New Connection Technique. 2007.
Mehr...

Jahresberichte und Newsletter des Fachgebiets Hochspannungstechnik und Asset Management